KryoFlux - Stress Testing

2010-01-22

Continuous (stress) testing revealed certain cases that would still trip the algorithm matching exact index position inside the current flux transition period (as we said before index detection is very exact, and is not altered to match a new flux period at all, like other imaging solutions), mostly due to index information being OOB data - and can and in fact does appear pretty much anywhere in the stream if we try long enough.

Rewritten the algorithm taking a very different approach to matching - it passes all edge cases previously discovered as well as new ones found.